... pardon me, but your split is showing ...
The Bad
Δ: mismatch percent as decimal [0.00]
H: even harmonic number
Fundamental, Result and Distortion for ONE frequency.
EVERY frequency has similar distortion.
Notice that the distortion waveform is not a sine!
Measuring Phase Splitter Distortion
Since the phase splitter is two signals of opposite polarity, we needed a way to measure them summed and independent of the rest of the amplifier. Solution is a
variable gain instrumentation amp.
InstAmp requires low noise ±15v supplies. Distortion lower than 0.002% of signal source. Input capable to 300+ VAC.
PCB, BOM & complete schematic available with a donation receipt to an animal welfare organization in your area.
Stock 2% Resistor Distortion
With the stock 30k 2% resistors [29.95 and 29.65], five valves all measure around 0.50% THD.
The NOS GE 12AU7 is a reference valve and has near perfect Gm match between each triode.
The R7 & L7 relative levels should be a warning to valve rollers. These valves had all been on for more than 24 hours. Deltas are much different after only a few minutes. Swapping L7 & R7 results in more than 3/4dB level shift.
Optimizing the Phase Splitter
The simple phase splitter circuit modification at left allows almost perfect balance in the Phase Splitter. The stock anode resistors are reduced by about 10% and a pot about 20% of that reduced value are inserted. e.g. 30k * 90% -> 27k * 10% -> 5k pot.
If the distortion can't be lowered below 0.1% or voltage across the resistors can't be balanced, replace the valve! Note that distortion is somewhat level dependent. Setting with an input level ≈150mV for unbalanced kit should give good results.
Power dissipated in the pot is minimal. Bourns 3296 0.5w power rating is ample. With 4mA/triode, a 5k pot dissipates 80mW, except in the case of a valve failure that sinks all the current through one triode and the pot is 0R on the other triode.
A more complex but robust version is shown at left. It has the advantages of minimal current through the pot and pot failure merely creating an imbalance rather than signal failure.
Calculate the values for the adjustable leg with 30k fixed resistor:
	• 2nd anode resistor is about 2.1x 1st anode resistor, ≈63k
	• dropping resistor between B+ and pot is about 1.6x anode resistor, ≈48k
	• pot is about 2/3 anode resistor, ≈20k. The pot is the more difficult element as they typically follow 1-2-5 stepping. You can either slug the pot or use a larger value giving a smaller adjustment range.
Circuits that don't use constant current device require a different adjustment arrangement as shown in this circuit from a Conrad-Johnson MV75a. Typically the 'dummy' side of the splitter has about 20% higher anode resistance with any trim. Adding a trimmer makes the math more complex...
Poor Man's Lab
PS balance can be adjusted with an AC voltmeter measuring between the output of the phase splitter blocking capacitors and the power valve grid input resistor relative to 0vA. 7 volts was the knee where the distortion began to increase rapidly. Typically around 2 or 3 should be fine. With a single voltmeter, start with the pot in the middle [≈5 turns from the click on either end]. Measure each phase and turn the pot to lower the higher voltage phase. Go about half the voltage difference, check the other phase and iterate until they match to 10mV. NOTE: As with all valve gear, it should be well warmed and not just pulled off the shelf after several months. We run an amp for 24 hours @ 10% rated power output in normal service orientation and covers for amps modified or just put in service.